Section 4 Component Teardown
4-40
Condenser Removal
To remove the condenser:
1. Disconnect power supply from unit.
2. Remove the front panel and cabinet wrapper/sleeve.
3. Discharge capacitor. To discharge the high voltage
capacitor, wait for 60 seconds and then short-circuit
the connection of the high-voltage capacitor (that
is the connecting lead of the high-voltage rectifier)
against the chassis with the use of an insulated
screwdriver.
4. Remove the fan and blower assembly.
5. Attach an approved self tapping line tap valve to the
process tube. Connect refrigerant recovery system
to tap valve. Turn on recovery system, open the
line tap valve, and allow refrigerant to flow into an
approved tank.
6. Disconnect inlet and outlet lines from condenser.
7. Using a 3 cornered file, score a groove around
capillary tube as shown. Break capillary tube along
score mark.
8. Extract the two screws securing the bottom of the
condenser to the unit base. (See Figure 4-104)
9. Carefully lift the condenser out from the unit base.
Evaporator Removal
To remove the evaporator:
1. Disconnect power supply from unit.
2. Remove the front panel and cabinet wrapper/sleeve.
3. Discharge capacitor. To discharge the high voltage
capacitor, wait for 60 seconds and then short-circuit
the connection of the high-voltage capacitor (that
is the connecting lead of the high-voltage rectifier)
against the chassis with the use of an insulated
screwdriver.
4. Remove the fan and blower assembly.
5. Attach an approved self tapping line tap valve to the
process tube. Connect refrigerant recovery system
to tap valve. Turn on recovery system, open the
line tap valve, and allow refrigerant to flow into an
approved tank.
6. Disconnect inlet and outlet lines from evaporator.
7. Extract the two screws securing the bottom front of
the evaporator to the unit base. (See Figure 4-105)
8. Carefully lift the evaporator out from the unit base.
Remove Screws
Figure 4-104.
Capillary Tube
To Compressor
Figure 4-105.
Remove Screws