Section 4 Component Teardown
4-37
Power Cord, Capacitor and Anion Generator
Removal
The power cord is secured to the unit frame with
two P-clamps and screws. The capacitor and anion
generator are secured with a single screw.
To remove the power cord:
1. Disconnect power supply from unit.
2. Remove the front panel and cabinet wrapper/sleeve.
Remove the control panel from its installation
position but do not disconnect from wire harness.
3. Discharge capacitor.
4. Extract the two screws securing the power cord
P-clamp at the base of the unit. (See Figure 4-95)
5. Extract the screw securing the P-clamp inside the
compartment. (See Figure 4-95)
6. Extract the top ground screw and remove the ground
wire lead for the power cord. (See Figure 4-95)
7. Disconnect the black and white wire leads of the
power cord from the control board. Power cord is
now free.
To remove the capacitor:
4. Follow steps 1-3 above.
5. Disconnect the wire leads from the capacitor.
6. Extract the capacitor mounting screw. Remove the
mounting strap and the capacitor is free.
(See Figure 4-95)
To remove the anion generator:
4. Follow steps 1-3 above.
5. Cut or remove straps securing the ionizer cable to
the unit.
6. Extract the bottom ground screw and remove the
ground wire lead for the anion generator. (See Figure
4-95)
7. Disconnect the black and white wire leads from the
control board that go to the anion generator.
8. Extract the anion generator mounting screw. Anion
generator is now free. (See Figure 4-95)
To discharge the high voltage capacitor, wait for 60
seconds and then short-circuit the connection of the
high-voltage capacitor (that is the connecting lead of
the high-voltage rectifier) against the chassis with the
use of an insulated screwdriver.
CAUTION
Capacitor
Anion
Generator
Ground Screws
Screw
Power
Cord
Ionizer
Cable
Capacitor
Mounting Screw
To
Control
Board
To Fan &
Compressor
Screw
Screws
Figure 4-95.
Not all wires shown for clarity.
P4
P3
P2
P7
BLUE
CN1
CN4
CN3
BLACK
BLACK
BLACK
CONTROL BOARD
EVAPORATOR SENSOR
AMBIENT SENSOR
WHITE
BLUE
GREEN
Y/G
FAN MOTOR
BLUE
DISPLAY BOARD
L
COM
N.O.
RY6
P8
P9
CN2
P5
RED
BLACK
ANION
Y/G
COMP
M
~
RED
Y/G
C
R
S
SUPPLY
POWER
WHITE
RED
YELLOW
CAPACITOR
ANION
Figure 4-96.
Vista de pagina 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 139 140