Section 2 Installation
2-16
Safety Bracket
Install Safety Bracket
Figure 2-47.
Sash Seal
Window
Locking
Bracket
Room
Flush
Room
C
Add 16- Or 18-
Gauge Angle
A
Add Angle To
Wood Stop
B
Add Wood
As Shown
Room
Figure 2-48.
Figure 2-49.
17. Hook the safety bracket over the base of the unit
and fasten it to the front of the platform assembly.
Use a #8-32 x 3/4-inch self-threading screw.
(See Figure 2-47)
18. Stuff the foam seal strip/sash seal between the
vertical sash and window glass (See Figure 2-48).
19. Use the window locking bracket to lock the inner
window sash to the base of the outer window sash.
Use one #8 x 3/4 inch screw, or #8-32 x 3/4 inch
self-threading screw. (Drill 1/8-inch pilot hole).
20. To replace the front:
First reconnect the coupler plugs, move the exhaust
control positioned through the front to the proper
location. Gently push the front into position on the
cabinet. It should click into place. Then replace the
retaining screws that holds the panel in place. Do
not push or pull the front panel louvers.
Alternate Window Jamb Applications
To install in windows having no flanges or wood stops
on the top and side jambs, the channels and panel
frame must fit against a mating flange (or 1/16-inch
max. thick angle) attached to the window jambs.
Figure 2-49 illustration A shows this angle installed.
Figure 2-49 illustrations B & C show alternate treat-
ments. On the sash side of the opening, the leading
corner of the inner sash becomes the flange. You can
purchase the angle strip locally.
The bracket prevents movement of the air conditioner
(either in or out) after completing the installation.
NOTE