Section 4 Component Teardown
4-6
Accessing the Control Board
The control board is secured with a screw to the control
box on the upper left hand side. (See Figure 4-11)
Pulling the control board out from its installation will
make accessing the remaining electrical components
much easier.
Before attempting to pull the control board from its
installation:
1. Disconnect power supply from unit.
2. Remove the thermalmastic from the wire harness
entering the control box.
3. Remove the wire harness from the retainer at the
back of the control box and cut all retaining straps.
4. Remove the power cord.
5. Disconnect the white wire at the top of the control
board at position N (AC-N1). Removing this wire
will allow you to pull the control board out from its
installation.
6. Disconnect wire leads from control board.
Thermistor connections at CN2 and CN3 may be
glued to the control board. Carefully remove glue
before attempting to remove the connectors.
Fan Motor Capacitor Removal
1. Disconnect power supply from unit.
2. Remove control board.
3. Disconnect wire leads from capacitor terminals.
Label as needed for proper reconnection.
4. Extract the two screws securing the capacitor to the
bottom of the control box. (See Figure 4-12)
Transformer Removal
1. Disconnect power supply from unit.
2. Remove control board.
3. Disconnect wire leads leading from transformer
to the control board (X115 and AC-N1 Blue wire).
Label as needed for proper reconnection.
4. Extract the two screws securing the transformer to
the bottom of the control box. (See Figure 4-12)
Terminal Block Removal
1. Disconnect power supply from unit.
2. Remove control board.
3. Disconnect wire leads from terminal block. Label as
needed for proper reconnection.
4. Extract the screw securing the terminal block to the
bottom of the control box. (See Figure 4-12)
Figure 4-11. FAM Series Shown
Figure 4-12. FAM Series Shown
Wires omitted for clarity.
White
Blue
Fuse
For Display
CN-4
X110
(Ionizer)
Control Board
Transformer
Screw
Ionizer in Blower Duct
XT1 Terminal
Block
Capacitor
Fan
Motor
Ionizer
Ground Screw
Locations
Ionizer Removal
1. Disconnect power supply from unit.
2. Remove control board.
3. Disconnect wire leads leading from ionizer to the
control board (X110). Label as needed for proper
reconnection. (See Figure 4-12)
4. Remove ionizer cable from installation in blower
duct. Feed cable through hole in control box.
5. Extract ground screw from bottom of control box to
free the ground wire leading from the ionizer.
6. Extract the screw securing the ionizer to the bottom
of the control box.
Comentarios a estos manuales