Section 4 Component Teardown
4-41
Compressor Removal
To remove the capillary tube assembly:
1. Disconnect power supply from unit.
2. Remove the front panel and cabinet wrapper/sleeve.
3. Discharge capacitor. To discharge the high voltage
capacitor, wait for 60 seconds and then short-circuit
the connection of the high-voltage capacitor (that
is the connecting lead of the high-voltage rectifier)
against the chassis with the use of an insulated
screwdriver.
4. Disconnect compressor electrical leads from control
board and capacitor. Feed wire leads through access
hole in control panel bulkhead into compressor area.
5. Attach an approved self tapping line tap valve to the
process tube. Connect refrigerant recovery system
to tap valve. Turn on recovery system, open the
line tap valve, and allow refrigerant to flow into an
approved tank.
6. Disconnect the compressor inlet line above the
accumulator. Disconnect discharge line one inch
from the outlet.
7. Use a 13mm socket or wrench and remove the 3
nuts securing the compressor to the unit base.
(See Figure 4-106)
8. R
emove the compressor electrical components by
using an 8mm socket or wrench and remove the nut
securing the cover to the top of the compressor.
Evaporator
Figure 4-106.
Condenser
Compressor
Nuts