Section 4 Component Teardown
4-5
Figure 4-8. FAM Series Heater Equipped Model
Left Bulkhead Partition (Heater Equipped Models)
The electrical component connections to the control
board are located in the control box located in the upper
left hand corner of the unit. The left bulkhead partition
must be removed first to access all the components in
the control box.
To remove the left bulkhead partition:
1. Disconnect power supply from unit.
2. Remove the front panel assembly. Pull the unit from
the cabinet wrapper/sleeve. Remove the blower
scroll front cover.
3. Pull thermistor from retainer on copper tubing.
4. Remove thermistor from retainer on evaporator.
5. Extract the screws on the left side of the bulkhead
partition. (See Figure 4-8) This will include the screw
securing terminal block to the left bulkhead partition.
6. Extract the screw from behind left bulkhead partition
and the screw securing the left bulkhead partition to
the top of the front partition. (See Figure 4-8)
7. Cut wire harness retaining straps, then pull apart to
allow access to the wire harness connections to the
electrical components.
8. The control board is mounted with a metal bracket
that slides over the top of the left bulkhead partition.
Carefully pull the control board out from inside
the compartment. Disconnect compressor and
condenser fan wire leads from control board,
capacitors and terminal blocks.
9. Disconnect red and white heater wire leads from
capacitor and terminal block.
10. Carefully pull the left bulkhead partition with the
electrical components off of the unit.
Power Cord Removal
To remove the power cord:
1. Disconnect power supply from unit.
2. Pull the unit from the cabinet wrapper/sleeve.
Remove the blower scroll front cover and left
bulkhead partition. Cut retaining straps securing the
wiring harness in the control box area.
3. Disconnect black wire from side 1 and white wire
from side 2 of terminal block XT1. (See Figure 4-10)
4. Extract the ground screw that secures the power
cord ground wire to the control box. (See Figure 4-9)
5. Cut retaining strap securing the power cord and
thermistor wires together, then remove power cord.
Screws
Screws
Screws
Screws
Figure 4-9. FAM Series No Heat
Screw
Power Cord
Power Cord Entering
Compartment
Screw
Screw
Screws
Transformer
XT1 Terminal
Block
Capacitor
Fan
Motor
Control Board
Figure 4-10. Control Box FAS Series No Heat
Wires omitted for clarity